| 马国华.基于超声波测流法导叶漏水量的测量研究[J].,2019,47(4):22-25. |
| 基于超声波测流法导叶漏水量的测量研究 |
| The Research of Measurement Method of Guide Vanes Leakage Based on Ultrasonic Flow Meterage |
| |
| DOI: |
| 中文关键词: 导叶漏水量 水电站 超声波 测量 |
| 英文关键词: the amount of leakage of guide vanes hydropower plant ultrasonic measurement |
| 基金项目: |
|
| 摘要点击次数: 572 |
| 全文下载次数: 136 |
| 中文摘要: |
| 导叶漏水量是评价水轮发电机组品质和状态的重要指标之一,其测量方法应结合电站实际情况合理选择。利用超声波测流法操作简便、测量时间短、测量精度高等优点,在某电站用超声波流量计开展了导叶漏水量的测量工作,试验结果基本满意,可为其它水电站导叶漏水量的测量提供参考。 |
| 英文摘要: |
| The amount of leakage of guide vanes is one of the important indexes to evaluate the quality and status of hydro-generating units. The measurement method should be reasonably selected according to the actual situation of power station. The means of ultrasonic ?ow measurement has the characteristics of simple operation, short measurement time and high precision,and in this paper the ultrasonic ?owmeter was applied to measure the leakage of the guide vanes in a power plant. The results were satisfactory and can provide reference for the measurement of the leakage of the guide vanes other hydropower stations. |
|